High efficiency heat recovery ventilation from Ubbink

HR GrandeBreathe Easy
The HR Grande provides high efficiency heat recovery ventilation to improve indoor air quality throughout larger houses and protect the fabric of the building. Its two EC/DC motors and sophisticated electronic controls ensure high performance with constant air flow and quiet efficient operation.

Energy positive ventilation
The HR Grande uses a heat exchanger to recover up to 95%* of the heat from the exhaust air and return it to the supply air. This helps to minimise the difference in temperature between the internal environment and the incoming air, reducing energy loss.

Operation
The HR Grande is powered by two vibration-free low noise EC/DC motors for quiet and cost-effective operation. It has three variable speed settings which can be adjusted from the control panel. The selected speeds can be easily controlled using the three speed switch. The standard three speed switch includes a filter change and fault indicator. The HR Grande can also be used with a range of sensors available from Ubbink, including humidistats, timers and PIR detectors. The incoming air is filtered to reduce pollen and dust and the outgoing air is filtered to protect the heat exchanger. The HR Grande has an integral condensate drain for the safe and effective removal of condensation.

Installation and maintenance
The HR Grande can be easily installed into lofts, cupboards or utility rooms, and wall-mounted using the brackets supplied. The constant velocity EC/DC motors mean that it is not necessary to balance the incoming and outgoing air volumes as the unit automatically sets this balance. Low-resistance ducting, available from Ubbink, should be used to minimise power consumption. Very little maintenance is required: simply remove and clean the filters every two months or as necessary. The filters should be replaced annually and the heat exchanger cleaned every three years. If installed in a cold loft the unit should be enclosed in a thermal jacket and all ducting should be insulated.

Options
Units are available with a factory fitted summer by-pass, so fresh filtered air can be introduced without being heated.

Dimensions

Specification

  High Medium Low
Air flow rate (m3/h) factory
default settings

325

200 100
Sound power level (dB[A]):
Break out
54 46 34
Extract air duct
47 40 32
Supply air duct
69 62 52
Power consumption (W)
132-175 55-67 21-23
Material
Powder-coated steel casing
Colour
Cream and blue/red
Weight (kg)
32
Maximum air flow rate setting
400m3/h
Maximum duct resistance
150pa at 400m3/h

* Measured in accordance with Netherlands standard NEN 5128 at the output and input points of the heat recovery unit. The amount of heat recovered from the exhaust air depends on a number of factors including the air flow rate, the volume of water vapour in the air and resistance in the system. The temperature of the return air will also depend on duct runs and the level of insulation. As a general guide in normal operating conditions a high efficiency heat recovery system achieving 95% under NEN 5128 would be expected to recover a minimum of 80% of the heat from the exhaust air.